First calibration — how much your extruder actually extrudes per command. This is the foundation for accurate and consistent prints.

Time
5–10 min
📊
Difficulty
Beginner
Impact
Critical
ℹ️
Why this matters: If your E-steps are wrong, every other calibration will be wrong. Temperature tower, PA, EM — they all assume the extruder is accurate. Get this right first.
1
Follow These Steps
📍
Mark your filament
Measure 120mm from the extruder entry and make a clear mark with a marker.
⌨️
Paste the command in the console
Use the Klipper command shown below to extrude exactly 100mm.
📏
Measure what is left
After extrusion finishes, measure the remaining distance between the extruder entry and your mark.
🔢
Enter the remaining distance
Type that remaining distance in the calculator. We calculate the real extrusion and give you the new firmware value.
Console command for Klipper
M83
_CLIENT_LINEAR_MOVE E=100 F=100
If your Klipper console does not support _CLIENT_LINEAR_MOVE, use this fallback:
M83
G1 E100 F100
⭐ Pro Tip
Do the test 2–3 times and average the results for best accuracy. Cold extruder = inaccurate results — always heat to print temperature first.
2
Calculator
mm
Fixed test values
Mark distance
120 mm
Extrude command
100 mm
mm
← Back to Calibration
Next: PID Tuning →
📋Calibration Order
Common Mistakes
Marking filament at wrong position
Using wrong units (mm vs cm)
Too much friction in the extruder
Not measuring straight with calipers
Not saving the new value to firmware