Reposit?rio

MMX

Um caminho completo do zero até uma configuração Klipper multicolor funcional: arquivos, BOM, montagem de hardware, fiação, configuração Happy Hare, calibração, primeira impressão e suporte.

v1.0AtivoPacote final de releaseKlipper
4 gatesConfigura??o de gates documentada
Type-AArquitetura do seletor servo
EBB42Placa de fia??o de refer?ncia
Happy HareSoftware Klipper MMU

Troubleshooting

SymptomLikely causeFix
Operation not possible. MMU has filament loadedGate sensor configured incorrectly or false positiveComment out MMU_GATE_SENSOR if you do not have a separate gate sensor.
Missing variables in mmu_vars.cfgKnown saved variables generation issueAdd mmu__revision = 0 to the saved variables file.
Pre-gate sensor does not changeWrong pin or pull-up conventionCheck the pin mapping and the ^ pull-up in mmu_hardware.cfg.
Cam ear never presses correctlyBelt/camshaft alignment issueLoosen belt, realign camshaft, redo empirical calibration.
Filament does not reach toolhead sensorGear calibration or friction problemRedo gear calibration and inspect PTFE tunnels/idler doors.